Industrial Air Cooled Chiller and Water Cooled Chiller: Optimal Cooling Solutions by Weeseng HVAC Technology Pte Ltd
Innovative Industrial Air Cooled Chiller Solutions
Weeseng HVAC Technology Pte Ltd provides clients with high-quality HVAC solutions tailored to their needs. Our Industrial Air Cooled Chiller shows our dedication to this project. Our air-cooled chillers efficiently remove heat from many industrial operations. These chillers are precision-engineered for durability.
This design optimises our Industrial Air Cooled Chiller's efficiency for prolonged operation in such an environment. Modern technology and sturdy construction provide heat transmission and temperature regulation, allowing your activities to run smoothly. These two make it possible.
Weeseng HVAC Technology Pte Ltd Superior Water Cooled Chiller is the best chiller according to our research. Central air conditioners and heaters run on Water Cooled Chiller Units. Their efficiency and low noise are well-known. Weeseng understands the importance of a Water Cooled Chiller in industrial and institutional temperature control. We take this seriously.
Since we use cutting-edge technology, our Water Cooled Chillers have the maximum cooling capacity and lowest energy usage. Our chillers maintain a steady temperature in the harshest industrial conditions.
Our Industrial Water Cooled Chiller and Industrial Air Cooled Chiller were designed for efficiency. We use cutting-edge construction and technology to make our chillers run efficiently and effectively. Weeseng chillers produce more, cost less, and have less environmental impact.
In summary, Weeseng HVAC Technology Pte Ltd distributes Industrial Air Cooled Chillers and Water Cooled Chillers. We're your partners in industrial cooling system design. To feel the Weeseng advantage, get a cutting-edge chiller today.
Weeseng industrial air-cooled chillers are custom designed and manufactured in Singapore to suit your specific industrial and commercial needs. The chiller is designed with air-cooled condensers for ready operation where water tower/ facility water supply is not readily available.
To ensure high product quality, easy user operation and maintenance, Weeseng leverages industrially recognized components for our air-cooled chillers which are designed to be compact and take up minimal floor space – all critical electrical and refrigeration components (air-cooled condenser, heat exchanger, water pump, control panel, water tank etc.) are integrated into the chiller unit.
Depending on your needs, our experienced team and local manufacturing capabilities allow for highly customized solutions (such as sub-zero cooling and split condenser design for further space optimization) that are available upon enquiry.
Weeseng Standard air-cooled chillers are also available in different capacities across a wide operational range (refer to specifications in the table below) for sale and/or rental to support all your industrial/ research process cooling needs.
The following is a summary of our air-cooled chillers specifications:
Model |
Unit |
WS - 101A |
WS - 201A |
WS - 303A |
WS - 403A |
WS - 503A |
WS - 803A |
Cooling Capacity* |
50 Hz Kcal/hr
60 Hz |
3,022
3,620 |
4,534
5,440 |
6,950
8,340 |
9,068
10,880 |
13,600
16,320 |
16,930
20,310 |
Condenser Air Flow Rate |
m³/hr |
1,290 |
1,935 |
2,967 |
3,870 |
5,805 |
7,225 |
Chilled Water Pump
Chilled Water Flow Rate
Water Tank Capacity |
KW |
0.4 |
0.6 |
0.8 |
L/min |
15/1.5 bar |
40/2 bar |
80/3 bar |
L |
15 |
30 |
50 |
Compressor Power Source |
|
200-240V 1PH(50/60Hz) |
200-240V
380-440V |
3PH (50/60hz) |
|
Total Running |
AMPS |
8.5
-
- |
12.8
-
- |
-
10.6
5.6 |
-
13.5
7.0 |
-
21.0
9.5 |
-
27.5
13.6 |
Height |
mm |
885 |
880 |
1,310 |
1,310 |
1,350 |
1,460 |
Width |
mm |
510 |
560 |
715 |
715 |
740 |
865 |
Depth |
mm |
635 |
815 |
840 |
840 |
890 |
1,220 |
Est.Machine Weight |
KG |
70 |
90 |
150 |
165 |
235 |
280 |
Model |
Unit |
WS - 1003A |
WS - 1503A |
WS - 2003A |
WS - 3003A |
WS - 4003A |
WS - 6003A |
Cooling Capacity* |
50 Hz Kcal/hr
60 Hz |
22,970
27,800 |
33,250
40,230 |
47,456
57,420 |
66,500
80,430 |
94,910
114,840 |
142,370
170,840 |
Condenser Air Flow Rate |
m³/hr |
9,805 |
14,190 |
20,253 |
28,380 |
40,506 |
60,759 |
Chilled Water Pump
Chilled Water Flow Rate
Water Tank Capacity |
KW |
0.8 |
1.5 |
3.0 |
4.0 |
7.5 |
L/min |
80/3 bar |
160/3 bar |
250/3 bar |
350/3 bar |
500/3 bar |
L |
50 |
120 |
200 |
300 |
450 |
Compressor Power Source |
|
200-240V
380-440V
3PH (50/60hz) |
380-440V 3 PH(50/60Hz) |
Total Running |
AMPS |
-
33.0
16.0 |
-
-
25.0 |
-
-
33.0 |
-
-
52.0 |
-
-
67.0 |
-
-
100.0 |
Height |
mm |
1,460 |
1,555 |
2,005 |
1,725 |
2,005 |
1,980 |
Width |
mm |
865 |
865 |
1,070 |
1,730 |
2,040 |
1,830 |
Depth |
mm |
1,220 |
1,425 |
1,730 |
1,730 |
1,730 |
3,050 |
Est.Machine Weight |
KG |
350 |
430 |
500 |
760 |
900 |
1,200 |
*Cooling capacity is based on the following conditions –
Chilled water leaving / entering temperature : 7 / 12 °C
Entering air-cooled condenser air temperature : 35 °C